Troubleshooting methods for common faults of metal detectors

Source: Time:2022-08-10 22:40:36 views:

Simple Troubleshooting Methods for Metal Detectors

Simple Troubleshooting Methods for Metal Detectors


1. Conveyor belt deviation

    1) Determine whether the tension of the conveyor belt is appropriate. If the conveyor belt is too loose, it is easy to deviate.

    2) On the pallet bracket of the conveyor belt, there are two adjustment bolts near the outlet end of the conveyor belt, through which the tension of the conveyor belt can be adjusted.

    3) Observe whether the tension of the two sides is consistent. If the tension of both sides is inconsistent, it will also cause the conveyor belt to deviate.

    4) Adjust the tension of the two belts to the same level through these two adjusting bolts to solve the problem of conveyor belt deviation.


2. The instrument has no sensitivity


    1) Check whether there are large metal foreign objects in the probe hole, such as coins, keys, screws, etc., and remove metal impurities.

    2) Whether the product selection is correct.

    3) Whether it is selected to be in the NG prohibited state, in this state, the instrument will not perform alarm and elimination actions when it detects any metal, but the signal indicator will indicate.

    4) If the above conditions are ruled out and the instrument still has no detection sensitivity, please call our company.


3. The instrument periodically false alarm


    1) Whether the conveyor belt is contaminated by metal impurities, if the conveyor belt is contaminated by metal impurities, the detector will alarm whenever the contaminated part passes through the detection area. Clean the conveyor belt to remove metal impurities.

    2) Even if the conveyor belt does not rotate, the instrument still periodically falsely alarms. At this time, there may be a high-power interference source around the detector, such as a vibrating screen.


4. The instrument alarms irregularly


    1) The detector occasionally has irregular false alarms, which may be caused by unstable power supply. This can be solved by adding a regulated power supply.

    2) When the product is not detected, the instrument is normal. When the product to be detected passes through the detection area, it still alarms even if the product does not contain metal impurities, which indicates that the detection parameters are not properly adjusted. Please refer to Chapter 3.

    3) If there is still a false alarm after the conveyor belt stops, check whether there are high-power interference sources around the equipment, such as motors, engines, etc.

    4) Check for large pieces of moving metal around the device.

    5) Check whether the grounding wire of the power supply is in good condition. In order to ensure the stable operation of the instrument, a solid grounding wire is required.


5. The motor does not start


    1) On the control box panel, lightly press the "Start" and "Stop" buttons to observe whether the relays in the control module are active. If there is any action, the motor is damaged or the starting capacitor is damaged. You can buy the same type of motor and replace it. Or contact the company's after-sales service department. Non-professionals are not allowed to repair without authorization to prevent the danger of electric shock.

    2) If the relay does not act, the control module may be damaged, or the connecting wire may be loose. Eliminate the loose connection cable and observe whether the fault is eliminated. If the motor still does not start, please also contact the company's after-sales service department. Non-professionals are not allowed to repair without authorization, in order to prevent improper repair and damage to other parts.


6. The product passes through the detector head, and there is no metal impurities, and the alarm is also issued


    1). When the product passes through the detector head, and there is no metal impurities, it will also alarm, indicating that the detection parameters are not properly debugged.

    2). Check whether it is a product that has been debugged. If the detection product is not set, you need to re-debug the detection parameters


Links
主站蜘蛛池模板: 亚洲欧美日韩在线一区| 日本www网站色情乱码| 精品国产一区二区三区av 性色| 成人毛片无码免费播放网站| 亚洲欧美另类在线图片区| 青青成线在人线免费啪| 日韩精品一区二区三区在线观看| 国产精品白丝喷水在线观看| 国产午夜福利精品一区| 国产亚洲无线码一区二区| 亚洲日韩av无码一区二区三区人| 天天影视网色香欲综合网| 国产精品白浆一区二小说| 精品人妻av一区二区三区| 少妇夜夜春夜夜爽试看视频| 99久久伊人精品综合观看| 欧美性色黄大片www喷水| 自拍 亚洲 欧美 卡通 另类 | 少妇无码吹潮| 精品香蕉在线观看视频| 老太婆性杂交视频| 国产精品99爱免费视频| 日韩中文字幕中文无码久本草| 久久er热在这里只有精品66| 日本乱子伦xxxx| 国产v亚洲v欧美v专区| 国产高清精品软件丝瓜软件| 14萝自慰专用网站| 国产精品白浆在线观看无码专区| 亚洲国产一区二区三区| 欧美成人一区二区三区在线视频| 久久/这里只精品热在线获取| 久久精品国产大片免费观看| 天天做天天爱夜夜爽女人爽| 国产精品天干天干在线观看澳门| 亚洲欧美国产精品久久| 亚洲www啪成人一区二区麻豆| 亚洲人成网站在线播放大全| 日韩人妻一区二区三区蜜桃视频| 精品少妇人妻av免费久久洗澡 | 无码人妻久久一区二区三区|